Findings

The Findings pane displays the finding/s for the currently selected event.

_images/inspections.findings.png

When the Finding Listing tab is active, then the Findings pane is hidden and the Finding pane is shown.

A Finding is the link between an Anomaly and an inspection or survey event. Findings are either escalated and linked to an Anomaly or deemed “insignificant” and remain simply as an observation on the source event.

Findings are automatically created on events when event data meets or exceeds the pre-configured anomaly criteria.

Example: An Anomaly trigger is defined on a CP event, where the CP reading value is outside -800mv and -1200mv, NEXUS IC will automatically create a Finding on that event when the event is created.

Findings will be created automatically when event data is imported from Excel.

A finding record has a Number, a Code, a Severity ranking, Reason (descriptive text) and Remedial Action (descriptive text). Upon review, if you deem that the Finding should be escalated to an Anomaly, then you should tick the Anomaly Required field, and choose an Anomaly from the list and linked to the Finding. If you click the Add button on the Select Anomaly dialog, the new anomaly will have the asset, code, and various other fields pre-populated for you.

Properties of a Finding

  1. Number - Optional. For use by users to label Findings.
  2. Event - The Event which this Finding is connected to.
  3. Code - Code which identifies the type of Finding. These are the same codes that are used to classify Anomalies. Some typical codes may include “CD”, “PD” or “VIB” (Coating Damage, Physical Damage or Vibration); however, anomaly codes are user-definable and can be configured from Configuration ‣ Anomalies.
  4. Severity - Choose from a list of pre-defined Severity Levels. Typical severity levels may include “Level 1 - Contributor”, “Level 2 - Degraded”, “Level 3 - Damaged”, “Level 4 - Danger” and “Level 5 - Extreme Danger”; however, severity levels are user-definable and can be configured from the Configuration ‣ Anomalies area. These are the same severities that are used to classify Anomalies. Anomaly severities can also be assigned to Anomaly Triggers.
  5. Reason - Text field. Size unlimited.
  6. Remedial Action - Text field. Size unlimited.
  7. Anomaly Required - Check this box if this Finding should be linked to an Anomaly.
  8. Anomaly - Anomaly that this Finding is linked to. This field only appears if Anomaly Required is checked.
  9. Anomaly Trigger - If this Finding was automatically generated by an Anomaly Trigger, that trigger is shown here.
  10. Is Auto Generated - True if this Finding was automatically generated by an Anomaly Trigger.

Report Table Sources

To extract Finding data into a report template, use the System Table titled Finding as the primary Table Source, or use the System Tables titled Event or Anomaly and then add fields from the Finding table. For more information see Report Templates.

The Findings Toolbar

Refer to section Findings Toolbar for full description of the this Toolbar.