Anomaly TriggersΒΆ
The Anomaly Triggers panel shows anomaly triggers assigned to the current asset. It may also show a preview chart, showing which triggers apply at which KPs or depths.
This panel only shows asset-specific anomaly triggers – it does not show triggers which may apply to event fields independent of asset. For example, if your Anode event is set to always raise a finding when its Depletion is greater than 75%, that would not be shown in this panel.
Anomaly triggers are pre-defined upper and lower bounds which are applied to event information. When the data bounds are exceeded, IC-Inspection automatically creates a Finding on the event.
Caution
In most cases, Findings are generated at the time events are added or imported. There are however some scenarios in which NEXUS IC’s Anomaly Triggers utility should be run manually. These are 1) whenever anomaly triggers are edited; 2) before any Finding review sessions; or 3) after a bulk import of event data (particularly when anomaly triggers rely on events other than itself).
Anomaly triggers can be configured on event fields in NEXUS IC in Event Types. Anomaly triggers for specific assets can be configured in NEXUS IC by right-clicking on an asset and choosing Anomaly Triggers....